680
PTC Types
25
Watt per cm²
1200
Volt
240
Degree Celsius
PTC Characteristics
Multi-voltage capability
Due to the PTC effect and the resulting variable resistance, semiconductors are multi-voltage capable in a defined range. For example, most PTC heaters can be operated at 230 V as well as at 400 V without any significant change in power.
Dynamic power adaptation
The power output of a PTC heating element depends on the heat extraction. If a lot of heat is extracted from the semiconductor, it automatically readjusts its temperature and increases its power. As soon as it reaches its maximum temperature, the power decreases again and hardly any current flows. This dynamic power adjustment makes PTC heating elements especially energy-efficient.
Self-limiting effect
Due to the logarithmic increase of the PTC's natural resistance in relation to the temperature, the PTC limits itself. As soon as the maximum temperature is reached, the semiconductor becomes non-conductive and settles due to the physical effect. Thanks to this effect, PTCs are particularly safe and do not require any additional thermal fuse.
Inrush current
PTC heaters experience an increased inrush current for a few seconds each time they are switched on. We therefore recommend to use a time-delay fuse in order to protect the application.
Current load for low voltage applications
For low voltage applications, the currents are much higher than for household applications (230 V) due to Ohm's law. Therefore, it is important to ensure a sufficiently large wire cross-section.
Power strongly dependent on PTC temperature
The power of a PTC heater is dependent on two factors: the temperature difference dT and the heat dissipating surface A. This relationship is described by the formula P = α * A + (dT), where α stands for the heat transfer coefficient. For an air heater, dT would be the temperature difference between the air and the surface of the heater.
Higher PTC temperatures (dT) allow for higher power outputs. For most applications, however, a temperature between 180 °C and 240 °C is recommended.
Increasing the heat dissipating surface area can also increase performance.
Customer application testing
When using PTC heating elements, we always recommend to run several application tests in order to confirm the correct and reliable function of the PTC heater using appropriate measurements.
PTC Applications
PTC heaters are perfectly suited for railway applications. With a limited temperature below 200°C, they are easier to handle according to fire protection standards and can also compensate for voltage fluctuations without a significant change in heating power.
Insulated PTC Air Heaters (HRP) were specially developed for use in ventilation systems. Thanks to their modular design, they can adapt to the cross-section of customers’ ventilation ducts, while also featuring a low pressure drop thanks to their delta-shaped fins. Low radiation and low temperature overshoot in case of failure make them also eligible for usage in EPP/EPS housings.
The combination of PTC effect and an thermally optimized aluminum profile makes the perfect convection heater. Depending on the outside temperature, the heater dynamically adjusts its power in order to protect components in electrical enclosures from frost and moisture. With the help of thermal simulations, a highly efficient aluminum profile has been developed which achieves high performance despite its compact and slim design.